Orthopedic implants are designed to restore movement and relieve pain, offering patients a second or even third chance at mobility. A hip or knee replacement is often framed as a durable fix, engineered to last for years, sometimes decades, inside the human body. And modern hip and knee implants exceed expectations, providing long service time and significantly improved life quality for the vast majority of patients. But durability inside biology, especially the human body, is never static once a foreign material is introduced. It responds continuously, at every scale.
“Having an implant in your body is going to change your body chemistry,” said Western University chemistry professor Yolanda Hedberg. “You might not get the corrosion and wear damage some people experience, but your body chemistry is constantly changing even if you don’t have any pain or other symptoms.”
A study, recently published in npj Materials Degradation (Nature Research), describes a project at Western and London Health Sciences Centre Research Institute (LHSCRI) that examined more than 240 retrieved hip and knee implant components to understand how and why they degrade over time.
Researchers, including Hedberg, Western chemistry postdoctoral associate Saman Nikpour and Schulich School of Medicine & Dentistry professor and LHSCRI scientist Matthew Teeter, combined optical microscopy with scanning electron microscopy and spectroscopy (scientific techniques used to analyze structure and composition of materials) to assign a score quantifying surface damage and identifying corrosion patterns.
Infection prior to or at surgery was correlated with higher damage scores of the trunnion (connecting point on an artificial hip where the top of the metal stem connects to the artificial ball) while inflammatory arthritis and cemented hip implants correlated with lower damage scores.
What emerged was a layered picture of mechanical and chemical change unfolding together inside the body. For both hip and knee implants, the dominant process of degradation was mechanically assisted corrosion, known as tribocorrosion. This type of corrosion occurs when movement and chemistry act on the same surface at the same time, accelerating damage beyond what either process would cause alone.
Teeter, director of Western’s Bone and Joint Institute, leads the Implant Retrieval Laboratory at LHSCRI, home to Canada’s largest collection of failed hip, knee, shoulder and dental implants.
“Collaboration is what lets us go deeper, into the mechanisms behind failure rather than just its consequences,” said Teeter, medical biophysics professor. “When you can connect implant design, materials and patient biology, you give manufacturers the evidence to build better devices and surgeons the insight to make genuinely patient-specific choices.”

Yolanda Hedberg

Matthew Teeter prepares for a scan at the Implant Retrieval Laboratory at LHSCRI, home to Canada’s largest collection of failed hip, knee, shoulder and dental implants. (Schulich Medicine & Dentistry)